1.0 Objective:
This SOP describes the procedure
to be followed for Cleaning of Microbiology Laboratory.
2.0 Scope:
This SOP covers the Cleaning of Microbiology
Laboratory
3.0 Responsibility:
Laboratory
Assistant: Responsible for the cleaning of the laboratory as per
procedure.
Microbiologist: Responsible for to check the
cleaning of microbiology department.
QA Officer/QA
Manager: Governing the document.
4.0 Procedure:
4.1 Clean the floor with 1 % Teepol by wet
mopping.
4.2 Clean the floor by wet mopping using
the following disintefectants :
4.2.1 Dettol solution : 5 % v/v (Dilute 50
ml to 1 litre with purified water).
4.2.2 Savlon solution : 5 % v/v (Dilute 50 ml
to 1 litre with purified water).
4.2.3 Triple 256 solution : 1 ml
to 256 ml with purified water.
4.3 Prepare fresh solutions every time.
Monday,
Thursday :
Dettol solution
Tuesday, Friday
: Savlon solution
Wednesday, Saturday :
Triple 256 solution
4.4 Clean the Laminar air flow bench by 70
% v/v Isopropyl alcohol.
4.5 Clean the sides and top of the Laminar
air flow with wet mop of Dettol / Savlon or Triple 256 solution.
4.6 Clean the incubator with 5 % v/v Dettol
solution or 70 % v/v Isopropyl alcohol.
4.7
Cleaning schedule shall be as
follows :
Sr.
No.
|
Area
|
Cleaning Agent
|
Frequency
|
1
|
Laminar Air flow work bench
|
Mopping with 70 % v/v IPA
|
Before and after each work
|
2
|
Out side wall and Top of Laminar Air flow
|
5 % v/v Dettol solution,
5 % v/v Savlon solution or Triple 256 solution
|
Once Daily
|
3
|
Floor
|
5 % v/v Dettol solution,
5 % v/v Savlon solution or Triple 256 solution
|
Twice Daily
|
4
|
Window, Door, Glass-panes
|
Wet mop with 70 % v/v IPA
|
Weekly Once
|
5
|
Walls and ceiling
|
Cleaning with 70 % v/v IPA
|
Fortnightly
|
6
|
Light Fixtures
|
Dry Cloths
|
Fortnightly
|
5.0 Precautions
5.1 Wear
nose mask while entering the Microbiology sterile area.
5.2 Switch
off the tube light or any other electrical fixtures while cleaning them. Do not
touch any eclectically equipment with wet hand.
5.3
Use either soft plastic broom or clean
cotton mops depending on the requirements.
5.4 Cleaning
items for microbiology area should not be used for other area.
5.5 Avoid
walking on wet floor after swabbing.
5.6 Change
the disinfectant solution, used for swabbing of the floors as soon as it
becomes dirty.