National Accreditation Board for Testing & Calibration Laboratories (NABL) is an autonomous society providing Accreditation (Recognition) of Technical competence of a testing, calibration, medical laboratory & Proficiency testing provider (PTP) & Reference Material Producer (RMP) for a specific scope
Pages
▼
Saturday, 22 December 2018
Describe the method of testing for checking of MOC of SS material (Molybdenum test)?
Procedure:
1.Put one drop of the electrolyte
solution of molybdenum test kit on the clean metal surface, which is to be
tested.
2.Switch on the detector and touch the
metal tip of the detector on the metal surface & carbon point in the
electrolyte solution.
3.Do not pass the current for more
than 3 to 4 seconds.
4.If the red color appears and is
stable for more than 2 seconds then it can be concluded that MOC of the part
being tested is SS-316.
5.If the solution remains colorless or
green color appears then it can be concluded that MOC of the part being tested
is SS-304.
6.If the black color appears & is
stable for more than 2 seconds then it can be concluded that MOC of the part
being tested is SS-302.